Prometheus
)
The system includes two fully integrated and humidified gas lines, which allows performing of all the basic fuel cell experiments, as well as basic electrochemical experiments.
The fully integrated software allows remote control of valves, heaters, mass flow controllers, pressure and humidity. The system is fully automated, allowing for unattended operation.
The testing station incorporates all necessary safety procedures, including nitrogen purge and emergency shutdown. All operating ranges, such as cell voltage, current, and temperature sensors, are paired with adjustable safety limits. The system is also equipped with a pre-installed hydrogen leak detector.
A range of additional accessories is available for purchase, including a piston cell holder, cell holder and current density & temperature monitor.
TECHNICAL PARAMETERS
Load Current | 60/120 A |
Load Power | 0.6/1.2 kW |
Voltage Range | Up to 60 V |
Mass Flow Controller | Anode: 2 SLPM Cathode: 5 SLPM |
Back Pressure (El. control) | 0 – 3.5 barg |
Dimension (WxHxL) | 490 × 522 × 800 mm 65 kg |