Wireless enclosure system for Zone 1 / 21 and Zone 2
Highlights of Wireless/network enclosure system for Zone 1/21 – 8265/5:
The well-established enclosure system (flame proof – Ex d) has been enriched with components like antenna bushings, antennas, Ethernet terminals, splice boxes. This set of tools enables the generation of project specific solution that combine easy of use with state-of-the-art explosion protection.
- Use of standard wireless/network devices in Zone 1
- Fast implementation of a customised or OEM solution
- A large selection of enclosure sizes
- Expert support from R. STAHL
- Simplified installation and maintenance thanks to separate connection chamber (optional)
- Flexible and safe connection of antennas
Highlights of Wireless/network enclosure system for Zone 2 – 9851/5:
Compared with solutions based on Ex d enclosures made of metal, the weight is reduced by up to 70%. The effort required for mounting is significantly reduced. The enclosure is made of glass fibre reinforced plastic, which allows the radio signals to be emitted, meaning that external antennas are not required. The connection is established via a separate connection chamber, which means that no access to the Ex nR enclosure is required and minimises maintenance work.
- Fast implementation of a customised or OEM solution
- No need to regularly check the tightness of the Ex nR enclosure part
- Five enclosure versions to choose from
- Expert support from R. STAHL
- Full range of cables for the field wiring
- Ceiling mounting permitted